DVP&R in Simple Terms
The DVP&R is a test plan and a results sheet in one. The plan half says what will be tested, how, to what acceptance criteria, how many samples, and when. The report half records whether each test passed. It is a common output of phase 2 of APQP and is often included in a PPAP submission as design verification evidence.
Many tests in the DVP&R come straight from the DFMEA, where they appear as detection controls.
Key Elements
- Test name and the requirement or specification it verifies.
- Test method and acceptance criteria.
- Sample size and build level (prototype or production intent).
- Responsible person and test facility.
- Planned and actual dates.
- Result: pass, fail or open, with a report reference.
Example
For a new door handle, the DVP&R lists a pull strength test, a 50,000 cycle durability test, a salt spray corrosion test and a cold temperature impact test. The cold test fails at first, the design is updated, and the DVP&R records the retest and the final pass.
Why It Matters
Without a DVP&R, testing is planned informally and gaps show up late. A complete plan proves to the customer that every requirement was checked. It is part of verification and validation work. OperaHive APQP software tracks APQP deliverables and gate reviews by phase.